Thermometric Titration Graph

Published 8 February 2026

Achievers dream - og thermometric titration graph v1

In this video tutorial, the objective will be to handle a thermometric titration in a chemistry practical.

Thermometric Titration Video

Watch the thermometric titration video on YouTube (opens in a new tab).
  1. In a thermometric titration, you carry out a reaction between two substances and use temperature measurements to determine the end point, which estimates when the reactants have reacted in their stoichiometric proportions.
  2. Additionally, students will be measuring the change in temperature over the course of the reaction.

The second step is crucial: recording the temperature after successive additions allows you to identify the change in the graph’s trend and estimate the end point. The temperature difference between only the beginning and the final reading does not locate the end point.

In that process, you can record your data in a format where it is easy to track the changes.

Thermometric Titration Key Points

A burette delivers titrant into a lidded insulated cup while a temperature probe is immersed in the liquid and kept clear of the cup.
Illustrative thermometric titration apparatus: add measured volumes of titrant to an insulated cup while monitoring the temperature. Open the diagram at full size (opens in a new tab).
  1. Begin with a recording of the initial temperature.

    This reading would usually be from the analyte which is placed in a beaker or in a styrofoam cup.

  2. Add fixed volumes of the titrant and record the temperature after each addition.

    Example: In the example described, students are instructed to add 5 cm3 at a time. After each addition, stir and record the highest temperature reached for an exothermic reaction, as directed by the practical instructions, and calculate the total temperature change from the initial temperature. An endothermic experiment may instead require the lowest temperature.

    Follow the volume increments and measurement instructions specified for your experiment; 5 cm3 is not a universal requirement.

  3. Once you have completed a full set of data, plot the total temperature change against the cumulative volume of titrant added.

    When recording the total temperature change, indicate whether it is a positive change or negative change by including the sign.

    ΔT = measured temperature − initial temperature

An illustrative table uses an initial temperature of 24.0 degrees Celsius to calculate signed temperature changes against cumulative titrant volume.
Illustrative recording table: calculate each temperature change from the same initial temperature and use the cumulative titrant volume. These are example values, not readings from the video. Open the diagram at full size (opens in a new tab).

Thermometric Titration Graph

Objective

(Refer to 2:22 of the video.) This section describes the thermometric titration graph discussed in the video.

The graph follows the total change in temperature (ΔT, in °C, on the Y axis) against the cumulative volume of titrant added from the burette (in cm3, on the X axis).

After plotting the points, draw two straight lines of best fit for the approximately linear regions before and after the end point, where this two-line method is required. Extend the lines to their intersection.

Some practicals ask you to plot the measured temperature rather than ΔT. Follow the stated instructions and label the Y axis accordingly. Subtracting the same initial temperature shifts the graph vertically without changing the end-point volume.

How to Draw the Titration Curve or Lines

  1. Draw the first straight line of best fit through the appropriate data before the end point. At zero added titrant, ΔT is zero by definition when using the recorded initial temperature as the baseline. Include this point where required, but do not force the fitted line through the origin unless the task or the chosen model requires it. An absolute-temperature graph does not generally start at (0, 0).

  2. As titrant is added, an exothermic reaction usually causes the temperature to increase. An endothermic reaction can cause the temperature to decrease.

  3. An exothermic titration may show a temperature maximum, while an endothermic titration may show a minimum. For the two-line method, use the intersection of the extrapolated lines to estimate the end point rather than assuming it is the highest or lowest individual reading.

    Beyond the end point, the reacting analyte has been consumed. The temperature may change because of dilution, the temperature of the added titrant and heat exchange with the surroundings. The second line can slope downwards, slope upwards or be nearly horizontal; it does not always have a negative gradient.

Schematic exothermic and endothermic thermometric titration graphs compare temperature rises and falls, fitted branches and endpoint estimation.
Schematic exothermic and endothermic examples. Estimate the end point using the required graph method and your actual readings; the post-end-point gradient is not universal. Open the diagram at full size (opens in a new tab).

Recording Small Temperature Changes

Record your measurements as observed, including a very small increase, decrease or no detectable change. Work with the data you have; do not add an expected decrease or adjust readings to force a trend.

Supplied video transcript excerpt

“For our second line of best fit, we know that it’s expected to have a negative gradient, the opposite gradient of our first straight line. That is because of the heat exchange to the surroundings.

However, in some scenarios when you carry out the same experiment, you may notice that there is a little to no change in the temperature and this may be very concerning during the experiment.

If you encounter such a situation, bear in mind that the practical expects a slight change in temperature and record it as a very slight decrease in temperature or a slight gradient. There is no need to try and force your results to fit the expected trend because students are expected to always try to work with the data that they have.”

Practical clarification: The quoted suggestion to record a slight decrease applies only if a decrease was actually measured. Record an unchanged reading if no change is observed. The post-end-point gradient is not universally negative. The supplied excerpt has not been independently checked against the recording.

Graph Intersection

The intersection labelled G in the video shows the estimated volume of titrant used at the end point. Read this volume from the X axis and use it to perform calculations.

Illustrative temperature-change data and two fitted branches intersect at an estimated endpoint volume of 23.9 cubic centimetres, separate from the highest measured point.
Illustrative end-point construction from two fitted branches. The example gives about 23.9 cm³; these values are illustrative and are not measurements from the video. Open the diagram at full size (opens in a new tab).

These calculations follow the same principles as other titration experiments, including calculations of the concentration of a solution and percentage purity. Use the balanced equation and the appropriate mole ratio.

Sources and Further Reading

Related article navigation:

Start Your Chemistry Tuition Journey With Achievers Dream

At Achievers Dream, we offer specialised Primary Science Tuition, O Level Chemistry Tuition, Lower Secondary Science Tuition and JC Chemistry tuition. Our teaching team includes former MOE Heads of Department, NIE-trained teachers and full-time tutors.

As a tuition centre in Singapore, students will be provided with a wide range of information from sources such as exclusive cheat sheets, sec 1 science notes, science revision guides or other supplementary/topic by topic notes.

Join Our Exclusive Telegram Group Here

Click Here for Free Access to our coloured Chemistry notes

We provide structured lessons with personalised support, alongside facilities such as our chemistry laboratory and a student portal. Our team will be there for you to support your learning journey, start now and achieve better results